Obelisc R Columns
Get In Touch
Obelisc R is a reverse-phase analytical column and can be used in traditional, reversed-phase type applications.
- Due to the presence of ionic groups and a long hydrophobic chain, Obelisc R offers additional retention and tuning that is not available with traditional reversed-phase columns.
- Multiple separation modes (RP, NP, IE).
- Mass spec, ELSD, preparative and low UV (
Obelisc R columns are available in all standard dimensions
Column IDs : 22 mm, 10 mm, 4.6 mm, 3.2 mm, 2.1 mm, 1 mm, 0.5 mm, 0.25 mm
Column Lengths : 250 mm, 150 mm, 100 mm, 50 mm, 25 mm, 10 mm
Particles : 10 um, 5 um
Pores : 100 A
Details will be updated soon……!
- HPLC Separation of Amino Acids, Bases, Acids, and Neutrals on Obelisc R
- HPLC Separation of Methyl Paraben, Benzonitrile, Propyl Paraben, and Toluene on Mixed-Mode and Reverse Phase Columns
- HPLC Separation of Polar and Hydrophobic Drugs on Obelisc R and N
- Separation of Chlorate, Perchlorate, and Phosphonate Ions
Analytical Columns
Part number | Phase | particle size (µm) | length (mm) | ID (mm) |
OR-03.100.0510 | Obelisc R | 5 | 100 | 0.25 |
OR-03.150.0510 | Obelisc R | 5 | 150 | 0.25 |
OR-03.250.0510 | Obelisc R | 5 | 250 | 0.25 |
OR-05.100.0510 | Obelisc R | 5 | 100 | 0.5 |
OR-05.150.0510 | Obelisc R | 5 | 150 | 0.5 |
OR-05.250.0510 | Obelisc R | 5 | 250 | 0.5 |
OR-100.100.1010 | Obelisc R | 10 | 100 | 10 |
OR-100.100.0510 | Obelisc R | 5 | 100 | 10 |
OR-100.150.1010 | Obelisc R | 10 | 150 | 10 |
OR-100.150.0510 | Obelisc R | 5 | 150 | 10 |
OR-100.250.1010 | Obelisc R | 10 | 250 | 10 |
OR-100.250.0510 | Obelisc R | 5 | 250 | 10 |
OR-100.025.1010 | Obelisc R | 10 | 25 | 10 |
OR-100.025.0510 | Obelisc R | 5 | 25 | 10 |
OR-100.050.1010 | Obelisc R | 10 | 50 | 10 |
OR-100.050.0510 | Obelisc R | 5 | 50 | 10 |
OR-10.100.0510 | Obelisc R | 5 | 100 | 1 |
OR-10.010.0510 | Obelisc R | 5 | 10 | 1 |
OR-10.150.0510 | Obelisc R | 5 | 150 | 1 |
OR-10.250.0510 | Obelisc R | 5 | 250 | 1 |
OR-10.025.0510 | Obelisc R | 5 | 25 | 1 |
OR-10.050.0510 | Obelisc R | 5 | 50 | 1 |
OR-21.100.0510 | Obelisc R | 5 | 100 | 2.1 |
OR-21.010.0510 | Obelisc R | 5 | 10 | 2.1 |
OR-21.150.0510 | Obelisc R | 5 | 150 | 2.1 |
OR-21.250.0510 | Obelisc R | 5 | 250 | 2.1 |
OR-21.025.0510 | Obelisc R | 5 | 25 | 2.1 |
OR-21.050.0510 | Obelisc R | 5 | 50 | 2.1 |
OR-220.100.1010 | Obelisc R | 10 | 100 | 22 |
OR-220.100.0510 | Obelisc R | 5 | 100 | 22 |
OR-220.150.1010 | Obelisc R | 10 | 150 | 22 |
OR-220.150.0510 | Obelisc R | 5 | 150 | 22 |
OR-220.250.1010 | Obelisc R | 10 | 250 | 22 |
OR-220.250.0510 | Obelisc R | 5 | 250 | 22 |
OR-220.050.1010 | Obelisc R | 10 | 50 | 22 |
OR-220.050.0510 | Obelisc R | 5 | 50 | 22 |
OR-32.100.1010 | Obelisc R | 10 | 100 | 3.2 |
OR-32.100.0510 | Obelisc R | 5 | 100 | 3.2 |
OR-32.010.0510 | Obelisc R | 5 | 10 | 3.2 |
OR-32.150.1010 | Obelisc R | 10 | 150 | 3.2 |
OR-32.150.0510 | Obelisc R | 5 | 150 | 3.2 |
OR-32.250.1010 | Obelisc R | 10 | 250 | 3.2 |
OR-32.250.0510 | Obelisc R | 5 | 250 | 3.2 |
OR-32.025.0510 | Obelisc R | 5 | 25 | 3.2 |
OR-32.050.1010 | Obelisc R | 10 | 50 | 3.2 |
OR-32.050.0510 | Obelisc R | 5 | 50 | 3.2 |
OR-46.100.1010 | Obelisc R | 10 | 100 | 4.6 |
OR-46.100.0310 | Obelisc R | 3 | 100 | 4.6 |
OR-46.100.0510 | Obelisc R | 5 | 100 | 4.6 |
OR-46.010.0510 | Obelisc R | 5 | 10 | 4.6 |
OR-46.150.1010 | Obelisc R | 10 | 150 | 4.6 |
OR-46.150.0310 | Obelisc R | 3 | 150 | 4.6 |
OR-46.150.0510 | Obelisc R | 5 | 150 | 4.6 |
OR-46.250.1010 | Obelisc R | 10 | 250 | 4.6 |
OR-46.250.0310 | Obelisc R | 3 | 250 | 4.6 |
OR-46.250.0510 | Obelisc R | 5 | 250 | 4.6 |
OR-46.050.1010 | Obelisc R | 10 | 50 | 4.6 |
OR-46.050.0510 | Obelisc R | 5 | 50 | 4.6 |
Guard Columns
Part number | Phase | particle size (µm) | length (mm) | ID (mm) |
OR-10.G.0510 | Obelisc R | 5 | 10 | 1 |
OR-21.G.0510 | Obelisc R | 5 | 10 | 2.1 |
OR-32.G.0510 | Obelisc R | 5 | 10 | 3.2 |
OR-46.G.0510 | Obelisc R | 5 | 10 | 4.6 |
OR-10.G.0510 | Obelisc R | 5 | 10 | 1 |
OR-21.G.0510 | Obelisc R | 5 | 10 | 2.1 |
OR-32.G.0510 | Obelisc R | 5 | 10 | 3.2 |
OR-46.G.0510 | Obelisc R | 5 | 10 | 4.6 |
Support will be updated soon…..!
Get Your Quote or Call: 040-29881474